BDEEB-s
£220.00 £198.00 +VAT

Instruments · Original EndoBender · Jordco

A bend at the last flute, not halfway up the shaft.

Anyone can put a curve in a file with pliers. Putting it in the right place is the difficulty. Bend too far up and the tip still points where it always did. Jordco use two matched jaws – a concave upper against a rounded anvil below – so that closing them bends the file, in their own words, up to the very last flute. That is the part that has to change direction if the tip is to find an orifice the shaft cannot see.

This item: Original EndoBender, designed by Dr L. Stephen Buchanan, surgical stainless steel, reusable and fully autoclavable
Made by Jordco, Inc.

Bends to the last fluteJordco’s claim for the matched jaws: the bend goes to the tip rather than stopping short of it
For small K-filesThe IFU is specific: a #10 or #15 K-file, bent at an acute angle to help locate and negotiate an orifice. Their worked example is the MB2 of a maxillary first molar
Thumb on the paddleNot squeezed like ordinary pliers. The IFU has the thumb on the raised paddle and the fingers securing the lower member – which is what gives the control to place a bend precisely
Steel, and autoclavableStainless steel and reusable. Pouched steam autoclave at 121°C for 30 minutes, or 132°C for 4 minutes pre-vacuum, after an enzymatic ultrasonic preclean

What it bends VDW C-PILOT® 008 and C-PILOT® 010, 25 mm – the small hand files this is made for.
The other Buchanan bender Buchanan EndoBender 2 – same designer, made by Plan B. We stock both and take no view.
Getting to the orifice Long Neck Carbide Bur 010 – the LN bur, for access and troughing.
Simpler alternative Endo File Pre-Bender – a different approach to the same job.

Why not just use pliers?
You can, and the bend lands wherever the jaws happen to grip – usually a few millimetres short of the tip. On a #10 file that difference is most of the point.

How is it reprocessed?
Preclean before use and between patients – brush off visible soil, then an ultrasonic bath with an enzymatic detergent only, one minute soaking and five sonicating. Then pouched steam autoclave: 121°C for at least 30 minutes, or 132°C for four minutes pre-vacuum. Retire it if you see excessive wear or the hinge joint starting to degrade.

How does it differ from the EndoBender 2?
Same designer, different manufacturer. We stock both and will not tell you one replaces the other – ring us and we will describe both.

Downloads

  Original EndoBender product sheet (PDF, 0.7 MB, Jordco) – the Gold Series design, the bending anvil and the materials.

  Original EndoBender instructions for use (PDF, 0.6 MB, Jordco) – how the bend is made, plus pre-cleaning and autoclave processing.

Original EndoBender by Dr L. Stephen Buchanan · bends small K-files to the last flute · surgical stainless steel · autoclavable · Jordco, Inc. · REF BDEEB-s