NeoSEALER EZFlo - bioceramic sealer that flows through a 29 gauge NaviTip

Obtura III Max Thermal Protectors (4)
Obtura III Max Thermal Protectors (4)

Obtura III Max Thermal Protectors (4)

OBT-823815
£18.00 +VAT

Wear parts · Obtura Spartan · Thermal protectors · 4

Patient protectionAutoclavable

The guard between a hot heating chamber and the patient

Obtura Spartan’s thermal protectors for the Obtura III Max. Everything attached to the heating chamber is hot, and the manual says to always fit a thermal protector in case of accidental patient contact. It goes over the needle nut and, unlike the handpiece, it can be sterilised.

This pack: 4 × Obtura III Max thermal protectors · pack of 4
Made by Obtura Spartan

PurposeObtura Spartan: designed to provide patient protection from the elevated temperatures of the heating chamber. The handpiece is not meant to touch the patient in normal use; the protector is for accidental contact
FittingOver the needle nut and the blue plastic Heater Nut, with its tab in the opening just behind the silver serial number ring. Unlatched and removed with the Multi-Tool
ReprocessingCleaned and sterilised before first use and after each subsequent use
DurabilityObtura Spartan say they have been tested to 250 reprocessing cycles. Inspect for wear and tear and replace as needed

Questions we get asked

How do I clean and sterilise them?
Obtura Spartan’s published steps: wipe off visible soil, wet a cloth and wipe, brush with a soft bristle brush, rinse under potable running water for 30 seconds, dry and inspect. Then pouch and run a prevacuum steam cycle, 132°C for 4 minutes, in an ANSI AAMI ST55 or ST8 compliant autoclave, with a 30 minute dry never above 137°C. Let them cool before use.

Can the handpiece go in the autoclave as well?
No. Obtura Spartan say the Obtura III Max handpiece is not autoclavable, and that only the thermal protectors are, once removed from it.

Do they fit an older Obtura?
Obtura Spartan list 823-815 as the Obtura III Max Thermal Protectors and say nothing about older units. If you run an Obtura II or an original Obtura III, ask us before ordering: 01733 404999 or sales@qedendo.com.

How many do I need?
They are cleaned and sterilised after every patient, so one is always in the cycle. A pack of four lets a busy list run without waiting for it.

The rest of the system

The unitObtura III Max System
Removed withMulti-Tool
Fitted overNeedle Nuts (2)
Also wearsPlunger Seal Assembly · Handpiece Bushing

Obtura III Max Thermal Protectors · pack of 4 · autoclavable once removed from the handpiece · Obtura Spartan · mfr code 823-815 · REF OBT-823815