X-Smart® Go · Dentsply Sirona · contra-angle sleeve, pack of 2
It looks like a hygiene item. It is actually the part that switches the apex locator on. Combined length determination – reading the canal while the file is cutting, which is the whole argument for a motor with the locator built in – is described in one instruction: “put the Protective Silicone Sleeve on the contra-angle (after it has been sterilised), connect the measuring cable to the handpiece and attach the lip clip”. No sleeve, no combined reading.
This pack: X-Smart® Go Contra-Angle Sleeve, two protective silicone sleeves per pack · REF B00XSGOAC0007
Dentsply Sirona · Class I medical device · steam-sterilisable, up to 200 cycles · the motor box ships two
| Fits | X-Smart® Go 6:1 contra-angle |
| What it does | Required for combined length determination – apex location while the motor runs |
| Sterilisation | 135°C for 10 min, or 134°C for 3 min · maximum 200 cycles · washer-disinfector permitted |
| Fitted | After the head has been sterilised, not before |
› The sleeve is an applied part in Dentsply Sirona's own definition, along with the head it covers and the measuring cable with its clips – so it is reprocessed before first use and between every patient.
› It goes through the same route as the head: pre-disinfect, brush or washer-disinfector, pouch, autoclave. Keep the two apart in the holder so they do not touch.
› Two per pack matches what ships in the box – one on the head, one coming clean – which is the minimum for running consecutive cases.
› Silicone tears and perishes long before 200 cycles are up in most surgeries. Cracks, deformation and loss of colour are the instructions' own signals to retire it.
Is this the same as the disposable handpiece sleeve?
No, and it is the confusion worth clearing up. This one is silicone, goes over the contra-angle, is sterilisable and enables the apex locator. The handpiece sleeve is a disposable barrier over the motor body, thrown away after each patient. Most surgeries need both.
Can I measure without it if I use a hand file?
Yes. Separate length determination runs off the file clip and lip clip with the motor idle. It is only the reading-while-shaping mode that needs the sleeve.
| Motor and head | X-Smart® Go motor · 6:1 contra-angle |
| Measuring | Cable · lip clip (5) |
| Maintenance | F-type spray nozzle · lubrication before every sterilisation |
| Isolation | HySolate dam · OraSeal™ · recommended by the instructions for apex locator accuracy |
X-Smart® Go Contra-Angle Sleeve (2) · protective silicone sleeve · required for apex location while shaping · Class I · steam-sterilisable 135°C/10 min or 134°C/3 min · maximum 200 cycles · 6-month warranty · Dentsply Sirona · REF B00XSGOAC0007
SpotlightRECIPROC® MinimaOne file · slim shaping for narrow canals
Shaping systems
Hand files & finders