ham

NeoSEALER EZFlo - bioceramic sealer that flows through a 29 gauge NaviTip

home > Access > Endo > MDT > Product
MONOSTERYL® Safe Ended Tapered Cone 21mm|014C
MONOSTERYL® Safe Ended Tapered Cone 21mm|014C

MONOSTERYL® Safe Ended Tapered Cone 21mm|014C

MDTE165-014C-10
£55.00 +VAT

MONOSTERYL® · E165 014C · 10

Sterile, ready to useSingle useSafe end

The safe end cone, sterile out of the wrapper

MDT’s E165 – a pointed-cone diamond with an uncoated tip, 1.4 mm across with a 9 mm head on a 21 mm FG shank; coarse grit, green ring – in MONOSTERYL® packing: the same bur as the standard pack, each one individually wrapped on a roll and gamma-sterilised.

This pack: MDT MONOSTERYL® E165 Safe End Diamond Bur, pointed cone with uncoated tip, FG, size 014, coarse (green ring), 21 mm, sterile, single use (Pack of 10, individually wrapped)

ShapePointed cone, uncoated tip (safe end) – MDT E165
Head1.4 mm diameter (size 014), 9.0 mm long
GritCoarse – green ring
ShankFG long, 21 mm overall
Pack10, individually wrapped on a roll
SterilityGamma irradiation; single use

Why MONOSTERYL? Convenience

Open the wrapper, fit the bur, use it, bin it. It arrives sterile, so there is no cleaning, bagging or autoclave cycle, and no used burs waiting to be reprocessed. Every bur you pick up is a new one.

What MDT say about it

›  MDT’s catalogue sets their diamonds at 60% diamond exposure against 40% for others – "More Diamond Per Diamond®" – listing "stronger bonding" and "uniform diamond coating, including the tips" among the features, and "faster & cooler cutting/grinding" and "slower clogging" among the benefits.

›  MDT say their “Triton” coating process "more than doubles the strength of the diamond bonding to the tool", on "Swiss-made heat treated and ground Stainless Steel shanks".

›  Speed, from MDT’s instructions for a 1.4 mm head: 70,000–220,000 rpm recommended, never more than 450,000 rpm.

›  Keep the bur moving and do not press hard – MDT warn that excessive pressure and a stationary bur both generate heat.

Is it any different from the standard E165?

No. MONOSTERYL® is MDT’s packing, not a different bur: MDT sterilise it by gamma irradiation and label it single use. Use it by the expiry date printed on the pack. The same bur comes non-sterile in fives: 21 mm or 25 mm.

Can it be autoclaved and used again?

No. MDT label sterile burs single use; once used, it is discarded.

Complete the set

Non-sterile, 5E165 21 mm · E165 25 mm
Coated tipBall-ended taper 011 · Ball-ended taper 015 · Ball-ended taper 018
The whole setEndo Access Kit

MONOSTERYL® E165 · 014 coarse, green ring · uncoated tip · 9 mm head · FG 21 mm · sterile, single use · Pack of 10 · REF MDTE165-014C-10 · Made by MDT Micro Diamond Technologies, Israel


carefully crafted bymmcpix.com
website and database designers