logged in as:
ham

NeoSEALER EZFlo - bioceramic sealer that flows through a 29 gauge NaviTip

home > Handfiles > C-PILOT® > VDW > Product
VDW C-PILOT® 08, 25mm (6)
VDW C-PILOT® 08, 25mm (6)
VDW C-PILOT® 08, 25mm (6)

VDW C-PILOT® 08, 25mm (6)

V040368025008
£14.80 +VAT
deals for this product
buy 10 in Handfiles to get 10.00% off
buy 15 in Handfiles to get 15.00% off
buy 5 in Handfiles to get 5.00% off

VDW® C-PILOT® ISO 008 · 25 mm · 6 sterile files

The size a calcified canal will actually let you start at

Ten minutes into a lower molar and the 010 is going nowhere? That is the ordinary experience of a sclerosed canal, and it is not a reason to open the access wider. ISO 008 is a fifth thinner at the tip than 010, which is often the whole difference between an instrument that stops at a constriction and one that slips past it. C-PILOT® 008 is built for exactly that moment: stainless steel, thermally hardened for bending strength, with an inactive pilot tip that is guided by the canal rather than by force.

0.08 mm
TIP DIAMETER
25 mm
WORKING LENGTH
6
STERILE BLISTER

This pack: 6 × VDW®STERILE C-PILOT® ISO 008, 25 mm, .02 taper · pre-mounted silicone stoppers · mfr code 368 025 008
Made by VDW GmbH, Munich, Germany

The patency instrument your file system already asks for

Read the instructions for most reciprocating systems and you will find a small hand instrument written into the sequence: check patency, and if the shaping file does not advance, create a glide path first. ISO 008 and ISO 010 are the sizes named for that job. Buying six of them is not an accessory purchase – it is the step that protects the far more expensive nickel-titanium file that follows, and the tooth it is working in.

At 0.08 mm the wire is very fine, so what it is made of decides how it behaves. VDW credit a special thermal hardening process with the file's high bending strength, and a laboratory comparison of pathfinding instruments in Endodontology in 2021 found the stainless steel files, C-PILOT® included, more resistant to buckling than the carbon steel and nickel-titanium instruments tested (Gupta and colleagues, DOI 10.4103/endo.endo_126_20). A bench test is not a clinical result – but buckling is precisely what an 008 does when the canal says no.

0.08 mm tipA fifth finer than an 010 at D0 – usually the step that finds a canal an 010 has been sitting on top of
Inactive pilot tipVDW's description: conducts the instrument safely along the canal, which is what keeps a fine file out of a false path
Thermally hardenedVDW attribute the high bending strength of the range to a special thermal hardening process
Radiopaque marksCalibration rings and a radiopaque stopper – useful when the file is too fine to see clearly on a film
Sterile, ready to useGamma sterilised to DIN EN ISO 11137, blister of six, no cycle before first use
Constant .02 taperThe ISO hand file geometry – the blade widens by 0.02 mm for every millimetre back from the tip, so the size you read is the size the canal gets

For probing in calcified root canals.
— VDW's stated indication for the C-PILOT® range. It is a scouting instrument, not a shaping one.

Using it

› Short amplitude – watch-wind in small arcs with the lightest apical load that still advances the file. Force at 008 buys a ledge, not depth.
› Pre-curve for a curve you can see – a slight bend at the last few millimetres helps the tip find the direction the canal is already going.
› Keep the flutes clear – irrigate and recapitulate rather than asking a lubricant to do it. Where a chelating gel is part of your protocol, File-Eze™ is the 19% EDTA option.
› Then hand over – once 008 is loose to length, move to 010 and only then to a mechanical glider.

Questions we get asked

Should I stock 008 or 006 as my rescue size?
008 first: it is the one you will use every week, and it is stiff enough to transmit a usable signal. Keep a blister of 006 behind it for the genuinely sclerosed cases, where 008 stops as well.

Can I autoclave and re-use them?
No. They arrive gamma sterilised in a single blister and VDW recommend single use of their pre-sterilised instruments. Since April 2007 the UK position has been that endodontic reamers and files are treated as single use and disposed of after each patient (CMO(2007)5, following the SEAC statement of 2006).

Six files for one canal – is that not a lot?
You will use more than one on a difficult canal, and a fine file that has been stressed is not one to re-introduce. Six is the sensible unit for a single sclerosed molar, not for six teeth.

Complete the system

Finer stillC-PILOT 006, 25 mm · for sclerosed canals
Next size upC-PILOT 010, 25 mm · the glide path reference size
Whole sequenceC-PILOT assorted 25 mm · two each of 006, 008, 010
Lubricant, optionalFile-Eze™ kit · 19% EDTA gel, if you use one
Mechanical glide pathWaveOne® Gold Glider 25 mm
Narrow anatomyRECIPROC® Minima R20 25 mm
Then shapeRECIPROC® blue R25 25 mm
Shorter accessC-PILOT 008 in 21 mm · posterior teeth, limited opening

VDW® C-PILOT® ISO 008 · 25 mm · .02 taper · calcified canals · patency · canal scouting · glide path · stainless steel · sterile · single use · 6 files · VDW GmbH · REF V040368025008 · also in 21 mm and 19 mm


carefully crafted bymmcpix.com
website and database designers